image1

ENEXIO WET COOLING TOWERS

EFFICIENT COOLING TOWER TECHNOLOGY FOR HIGH-PERFORMANCE SOLUTIONS.

We design, manufacture, and service cooling towers for the energy and processing industries. More than 50 years of experience and success have made us a major global player in planning and implementation of wet cooling towers. Our Competence Center for wet cooling towers can offer any type of cooling tower design, including counter-flow and cross-flow solutions, with an extensive variety of technologies and concepts. The wide range of ENEXIO cooling tower designs ensures all cost and environmental requirements, and minimize operational and service costs.

A LONG-STANDING HISTORY BASED ON EXPERIENCE AND TRUST

The former Power Cooling division of GEA Group AG - ranges from Air Cooled Condensers, Heller Technology® and Wet Cooling Towers including Service for Wet and Dry applications to 2H Water Technologies – operates separately and independently under the name ENEXIO.

ENEXIO WET COOLING TOWER SERVICE

WE PROVIDE MAXIMUM PLANT AVAILABILITY

image2

The cooling tower competence-center by ENEXIO Service - We can deliver all kinds of service for all circumstances at your plant.  


The use of further-developed components with new technologies goes hand-in-hand with a higher cooling performance, lower power consumption and a low noise development. ENEXIO Service analyzes the inventory and the potential for improvement at the customer’s plant, so that an ideal and customized solution can be found. The amortization of such modernization can usually end up being quite short, especially when the modernization is combined with comprehensive maintenance.



COOLING TOWER FILLS

image3

CROSS-BRAND VARIETY OF COOLING TOWER FILLS


An economical and ecological cooling tower operation requires the use of high-performance fills and efficient drift eliminators. The evaporative cooling tower is still the most economical way of water cooling at industrial and power plant locations.  As the pioneer for fills and drift eliminators made of plastics, we help our customers to meet their high demands.


OUR PRODUCT AND SERVICE RANGE:


  • Spare parts delivery and installation
  • Service framework agreements
  • Service and maintenance
  • Plant assessments and plant check
  • Inspections and evaluations
  • Installations and removals
  • Cleaning work
  • Complete replacement of heat exchanger bundles and fills



  • Overhaul and upgrade of fans, motors and gearboxes
  • Refurbishment, increase in efficiency and optimization of  cooling towers of all kinds
  • Complete overhaul of the entire cooling units and systems
  • Construction of fan-assisted cooling towers
  • All work, including necessary engineering services and procurement, from one single source

image4

ENEXIO INDUCED DRAFT AIR COOLED CONDENSER

INAIR - THE INNOVATIVE AND INTELLIGENT AIR COOLED CONDENSER SYSTEM

From the company who invented the Air Cooled Condenser, comes the next generation of innovative and intelligent design.

  

The InAIR combines proven components and technologies to yield the next generation in dry cooling: an Air Cooled Condenser featuring induced draft fans. Induced draft fans have been used reliably in the majority of power plant main cooling systems worldwide, like in wet cooling tower applications. Now, through innovative engineering and utilization of our self-supporting ALEX bundles, ENEXIO can offer the InAIR, an Air Cooled Condenser which offers the superior operational performance.

PRIMARY BENEFITS WITH INDUCED DRAFT FANS: 


  • Reduced air inlet and total height of ACC: less visual impact
  • Smaller footprint of columns
  • Reduction of steel structure quantities (up to -60%)
  • Reduction of steel structure weight (up to -50%)
  • Reduced costs for construction (-10% to -25%)
  • Reduced construction duration:  20% to 30% decrease in man-hours for erection work
  • Easier pre-assembly at grade
  • Inherent design of supporting steel structure greatly reduces the requirement of scaffolding
  • Reduction in the length of the main steam duct
  • Reduced investment costs
  • Shorter delivery and erection periods
  • Patented around the world

NO FAN BRIDGE NEEDED:


  • In a classic forced draft Air Cooled Condenser, the fans are exposed to an elevated level of dynamic loading. The vibrational effect of dynamic loading can be mitigated by calculation and design – but not eliminated. The InAIR Air Cooled Condenser resolves this weakness in the Classic ACC design.

image5

CONTACT ENEXIO

ENEXIO USA, LLC

17757 US Hwy 19 North, Suite 275, Clearwater, FL 33764